Computer Aided Partial Discharge Measuring System
FAAB003
Hardware: ●IBM compatible Personal Computer:Intel Pentium Processor / 32MB RAM / Data Acquisition Card / VGA / TFT Matrix display ●19" Industry PC or Desktop Specifications: ●Maximum detectable apparent charge: > 10000pC ●Minimum detectable apparent charge with 50Ω imput impedance:< 1pC ●Upper limited frequency:30MHz ●Bandwidth of PD-measurment:300kHz ●Digital input of signals:12bit Software Automation & Control & Protocol Interface: ●On-Line transfer to spread sheet or data base software ●All types of protocols and scoring sheets can be compiled and modified at any time ●OLE interface ●Complete software based remote control is possible ●Use object links in order to combine stored program controllers with measurment devices